Troubleshooting guide
iNetVu Troubleshooting Guide
C-COM Satellite Systems Inc.
Page 76 of 88
Step 4:
• Disconnect the coax cable going into the “RX” port on the base plate of the antenna.
• Measure voltage on this cable. If the voltage does not match the output of the controller,
replace the cable.
• If the voltage does match, reconnect the cable and proceed to Step 5.
Step 5:
• Disconnect the coax connecting to the LNB.
• Measure voltage on this cable. If the voltage does not match the 7000 Controllers output, it
concludes it’s an issue with the internal wire. Please contact C-COM Technical Support for
assistance.
• If the voltage does match, it concludes the LNB is the issue. Please replace the LNB and try
again.