Troubleshooting guide
iNetVu Troubleshooting Guide
C-COM Satellite Systems Inc.
Page 53 of 88
Centering the AZ/PL Potentiometer
Azimuth Potentiometer
AZ Pot locations: 1200, 1500, 1800 (left) 980, 750 (right)
Gear underside of AZ Potentiometer
To center the AZ Potentiometer:
1. Ensure the antenna is physically in the center position on Azimuth before continuing.
Disconnect the sensor cable and manually move the antenna (visually verifying).
2. Locate and remove the azimuth potentiometer.
3. Rotate the potentiometer gear counter clock wise until it stops.
4. Rotate the potentiometer gear clock wise until it stops. A full rotation from one extreme should
be 10 full turns. (if the gear continues turning indefinitely please contact C-Com Technical
Support).
5. Rotate the potentiometer gear five (5) full rotations to approximately center it.
6. Carefully reinstall the potentiometer.