Over-Current Protection
Error Code Definition:
*****Error Code--Stopping Motor, Setting System to IDLE *********
* 0x9000---EL Hardware Over-Current Protection
* 0x9001---AZ Hardware Over-Current Protection
* 0x9002---PL Hardware Over-Current Protection
* 0x9003---EL Over current 3 seconds
* 0x9004---AZ Over current 3 seconds
* 0x9005---PL Over current 3 seconds
Current used to move the Platform exceeds the fixed limit, which resulted in a current spike.
1. Ensure the correct platform Type is selected with the correct version and serial number.
2. Check the Speeds and Limits for all angles to verify that they are at default. Please see “Default
Limits and Configuration Data Tables” in the 7000 Series Controller User Manual. Reselecting
the Platform Type will reset these to their default values.
3. If there is any snow/ice build up or if the unit has been idle in below freezing (-25 to -30 +)
temperatures for extended periods of time. You may have to move the unit indoors to free the
platform up. Remove the Sensor Cable and attempt to move the antenna manually with HI Speed
ON from the front panel controls. Reconnect the sensor cable and try deploying again.