4. If the Mobile Platform physically moves but will not rotate to both extremes
(Applies to 1.2M platforms only) The possible cause will be the Rear Bearing separating from the Rear
Bushing.
a. Using the manually controls rotate the Polarization to both extremes. If you see the bushing
separating in either the -90 or 90 positions they will need to be re-positioned.
b. Loosen the two set screws and push the Bearing and Bushing back together so they are flush.
c. Tighten the two set screws.
d. Attempts to move the Polarization to both extremes. The Polarization should move freely with out
any jam or over current errors. Please contact C-COM Technical Support for further assistance.
Set Screws (2)
Rear Bearing
Rear Bushing
The separation will
occur here