Datasheet
5.2 TEST METHOD & PERFORMANCE
Unit
mAh
Voltage
(V)
mΩ/cell
minute
A
mAh
cycle
50-cycle test as per above table is repeated . The discharge time of the
100th, 200th, 300th, 400th, 500th should be more than 3 hours
respectively. (Ambient temperature is 20±5)℃
5.3 Humidity
The cells shall not leak during the 14 days when it is submitted to the
condition of a temperature of 33±3 ℃ and a relative humidity of
0.25CmA for 2.33h
BYD: Specification of D-SC2100P
ConditionsSpecification
0.25CmA to 1.0V/cell
Overcharge
Charge Retention
Maximum continuous
discharge current
Standard charge
before discharge
Open Circuit
Voltage(OCV)
≥1.25
≥54(1890mAh)
≤30
Internal
impedance
≤10
Capacity
0.1CmA for 16h
2~48
49
50
0.25CmA for 3.17h
0.25CmA for 3.17h
Cycle Life
0.20CmA to 1.0V/cell
RemarksTest
80±5% (salting is allowed).
1 0.1CmA for 16h
-Confidential. Please keep integrated.-
The content of this document is the property of BYD Company Limited. It is to be treated strictly confidential and is
not to be disclosed, reproduced, or used in whole or in part without written consent.
none
none
none
1~4h
0.25CmA for 2.33h
up to 3 cycles
are allowed
Cycle number Charge
Leakage
≥2100
Standard
charge/discharge
After 1 hour
standard
charge
210 mA(0.1C) charge
for 28 days
DischargeRest
standard charge;
storage: 28 days
Standard discharge
IEC61951-1
High rate
discharge(1C)
End Voltage is
1.0V/Cell
page 3 of 5
Upon fully charge
(1KHz)
Note 3 IEC61951-1 cycle life
no leakage
nor explosion
Discharge current
(C)
Fully charge at 2100
mA(1C), then storage
14 days
see note 3
≥1470
≥500
no leakage nor
deformation