Datasheet

5.4 Vibration
Cells shall be mechanically and electrically normal after vibration which
has an amplitude of 4mm(0.1575 inches) a frequency of 1000 cycles
per minute, which should be continued in any directions during 60 minutes
5.5 Shock
Cells shall be mechanically and electrically normal after being subjected
to a drop from a height of 450mm (17.716inches) onto an oak board in
a voluntary axis respectively 3 times.
5.6 Short
Cells shall not explode after 1 hour short-circuit test.
5.7 Incorrect polarity charging
Cells shall not explode after 5 hour of incorrect polarity charing at 1 CmA.
6. PRECAUTION
6.1 We recommend you to set the cut-off voltage at 1.0V/cell.
6.2 If it is below 1.0V/cell, cells may have over-discharged or reverse charged.
6.3 Do not detect -V for first 5 minutes of charging.
6.4 The cells shall be delivered in discharged condition, Before testing or
using, the cells shall be correctly charged in accordance with this specifications.
7. WARNING
BYD: Specification of D-SC1300P page 4 of 5
7.1 Avoid direct soldering onto cells.
7.2 Observe correct polarity when connecting.
7.3 Do not charge with more than our specified current.
7.4 Use only within the specified working temperature range.
7.5 Do not subject cells or batteries to mechanical shock.
7.6 Do not mix cells of different manufacture,capacity,size or type within a battery.
8. DANGER!
8.1 Avoid throwing cells into a fire or attempting to disassemble them. As the
electrolyte inside is strong alkaline and can damage skin and clothes.
8.2 Avoid short circuiting. It may be leakage.
-Confidential. Please keep integrated.-
The content of this document is the property of BYD Company Limited. It is to be treated strictly confidential and is
not to be disclosed, reproduced, or used in whole or in part without written consent.
7.7 Seek medical advice immediately if a cell or battery has been swallowed.
7.8 When disposing of secondary cells or batteries ,keep cells or batteries
of different electro-chemical systems separate from each oter.
7.9 Do not maintain secondary cells and batteries on charge when not in use.