Figure 8: Configuration Notice Figure 9: Inverter Configuration
Choose the inverter your battery is going to operate with in Figure 9. If the one you intend
to choose is not in the list, check the latest version Compatible Inverter List (or Minimum
Configuration List) first.
The Model in that page (Figure 10) means the model of the battery.
For one LVS/LVS Lite stack, maximum 6 modules is allowed in one tower. But for two or more
than two towers connected in parallel, maximum 4 modules are allowed in each tower.
For LVS/ LVS Lite and LV Flex/LV Flex Lite, the quantity you are going to choose is the total
battery modules of the whole battery system. (Figure 10)
For HV (HVS/HVM/HVL) battery system, if you add new modules to the existing system,
please make sure the SOC of the new module be approximately as the same as the existing
system. It is quite important. Otherwise you may lose some capacity without further
calibration.
For the LV (LVS/LVL/LV Flex, etc.) battery system, the configuration of the application mode is
also necessary. Wrong configuration could make your system not work in an ideal model.
You can also do the configuration in the main menu. (Figure 12)
Figure 10: System configuration