B-Box HV Installation Guide

BYD Battery-Box HV User Manual
3 Technical Data
Model
Battery-Box H 5.0
Battery-Box H 7.5
Battery-Box H 10.0
Battery Module
B-Plus H 2.5
2 modules
3 modules
4 modules
Usable Energy (kWh)
1
5.12
7.68
10.24
Max Output Power (kW)
5.12
7.68
10.24
Peak Output Power (kW)
7.17, 10s
10.75, 10s
14.34, 10s
Round-Trip Efficiency
≥95.3% (Under test conditions [1] )
Nominal Voltage (V)
204.8
307.2
409.6
Operating Voltage Range (V)
160~225.6
240~338.4
320~451.2
Communication
RS485/CAN
Dimensions (WxDxH) (mm)
590×350×758
590×350×994
590×350×1230
Net Weight (kg)
99
139
179
Enclosure Protection Rating
IP55
Operating Temperature Range
2
()
-10~+50
Certification Plan
UL1642 / UL1973 / FCC / UN38.3
Scalability
To be announced
Compatible Inverters
Please refer to the Compatible Inverter List
When BYD Battery-Box HV operates in low temperatures, the charge and discharge current is adjusted
automatically. The battery will limit the current when the operating temperature gets low. Please refer to the table
below for current parameters related to operating temperature:
Charge Current at Various Temperatures Ranges
Temperature Range ()
Normal Current(A)
-10~0
0.2C
0~10
0.5C
10~50
0.8C
Note: It will take 2 minutes for the charge current to adjust
Discharge Current at Various Temperatures Ranges
Temperature Range ()
Normal Current(A)
-10~40
Discharge current is limited to 1.4C.
If the actual discharge current is more than 1.2C, it
will be limited to 1C after 10 seconds and the current
will be recovered to 1.4C after 2 hours.
40~50
0.5C
1
Test conditions: 100% DOD, 0.2C charge & discharge @+25
2
-10~10 will be derating
* System Usable Energy may vary with different inverter brands