Installation Manual
NÜO PASS Manual
Introduction
5
Features Wiring
The NÜO PASS incorporates a male overhead connector.
NÜO PASS is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector
at one end to correctly connect it.
The other end of the piped cable is connected to a single door controller or to the corresponding Wili
following the simple colour coding.
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input/
output readers or with 2 readers that are very close together.
TYPE OF WIRING AND WIRING DISTANCE:
WIRING SPECIFICATIONS:
DISTANCE BETWEEN READERS:
The wiring distance from the reader and the single door controller or Wili should not
exceed 25 metres in length under any circumstances.
Orange
O/W
Green
-
A
B
+
BYBU S
G/W
3.5 metres of cable
NÜO PASS