Installation Manual
NÜO PASS Manual
Introduction Features
4
Technical Specications
TECHNICAL SPECIFICATIONS
NÜO PASS:
INPUT VOLTAGE 24 VDC (11 - 28 VDC)
MAXIMUM POWER 5 W
READING DISTANCE 3 - 5 cm
FINGERPRINT SENSOR TYPE Optical
SENSOR RESOLUTION
500 dpi
MAX. NO. FINGERPRINTS 9,500 ngerprints (1:1) - 1,000 (1:N)
COMMUNICATIONS BUS RS-485
INPUTS 1 Door sensor input
OUTPUTS
1 Output for lock control
24 vDC / (250 mA maximum)
ILLUMINATION
Colours according to status:
RED/WHITE: Terminal oine
DEGRADED RED/PINK: Terminal in enrolment mode
FLASHING BLUE: Terminal in rmware update mode.
BLUE: Terminal on standby / standard security
GREEN: Access granted / Unrestricted
RED: Access denied / Door blocked
WHITE: Reading ngerprint/card
FLASHING WHITE: Fingerprint enrolment
PURPLE: High security mode
PINK: Very high security mode
YELLOW/GREEN: Emergency
FLASHING YELLOW: Connected but not congured
AUDIO
Dierentiated sound indicators for granted and denied access
and statuses.
OPERATING
TEMPERATURE
-10 °C to 50 °C
READER DIMENSIONS 140 x 80 x 54 mm (height x width x depth)