User manual NÜO SWIP 41908
NÜO SWIP Manual 2
NÜO SWIP Manual Introduction NÜO SWIP GENERAL FEATURES NÜO SWIP (Ref. 41908) -- NÜO SWIP high-end biometric reader with capacitive sensor. -- Display with events and time. -- High resolution 508 dpi capacitive fingerprint sensor. -- Maximum security proximity reader for 13.56 MHz contactless MIFARE Plus®, MIFARE® DESFire EV1, MIFARE® Classic and MIFARE Ultralight® cards. -- Identifies fingerprint in less than 0.5 seconds when operating at 1:1, less than 1s at 1:20, and less than 1.5s at 1:100.
NÜO SWIP Manual Introduction NÜO SWIP Technical Specifications TECHNICAL SPECIFICATIONS NÜO SWIP: INPUT VOLTAGE 24VDC (11 - 28 VDC) MAXIMUM POWER 2 W without lock - 8 W lock activated READING DISTANCE 3 - 5 cm FINGERPRINT SENSOR TYPE Capacitive sensor SENSOR RESOLUTION 508 dpi MAX. NO. FINGERPRINTS 100 Fingerprints COMMUNICATIONS BYBUS RS-485 By Protocol: BYBUS high security communications.
NÜO SWIP Manual Introduction NÜO SWIP TYPE OF WIRING AND WIRING DISTANCE: The NÜO SWIP incorporates a male overhead connector. NÜO SWIP is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector at one end to correctly connect it. The other end of the piped cable is connected to a single door controller or to the corresponding Wili following the simple colour coding. + A B BY B U S Naranja N/B Verde V/B 3.
NÜO SWIP Manual Installation Wall mounting -- TERMINAL MOUNTING: 1) Anchor the base piece to the wall using the screws and wall plugs provided. Make an opening for the cable. X 2) Pass the reader connection cable through the hole in the base piece. X X X The head of the figure in the drawing should be pointing upwards. Recommended height for installation: 1.2 - 1.5 m. 3) Place the reader by inclining it at an angle of about 45 °C for the tabs on the base to hook together.
NÜO SWIP Manual Installation connections NÜO SWIP readers can be directly connected to two types of devices depending on the architecture of the installation: -- Connection to a Wili. -- Connection to a single door controller. The connection to be made for both types of devices is exactly the same. The colour code must be followed. For more detailed information, consult the equipment manuals referenced earlier.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipmentÿ Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.