User Manual

NÜO Flux Manual
Installation
10
Wiring
NÜO FLUX readers can be directly connected to two types of devices depending on facility architecture:
- Connection to a Wili.
- Connection to a single door controller.
The connection to be made for both types of devices is exactly the same. The colour code must be fol-
lowed. For more detailed information, consult the equipment manuals referenced earlier.
READER WIRING:
Respect the specied input voltage.
Install the reader using voltage-free power cables.
NÜO readers support an input voltage ranging from 11 to 28 VDC.
24 VDC is recommended in order to avoid possible voltage drops.
These signals must be perfectly isolated in order to prevent damaging the equipment or in-
stallation.
Orange
Orange/White
Green
RS-485-A
RS-485-B
+ 24VDC
BY B U S
Green/White
0V / GND
COLOUR
SIGNAL