User Manual
ImpactXtreme Operator’s Manual 8 March 2013
Specifications
Text in red is for EXAMPLE ONLY, borrowed from GasAlertQuattro
Dimensions
Standard version with clip: 138 by 97 by 65 cm (54.3 by 38.2 by 25.6 inches)
Wireless version with clip: 138 by 121 by 65 cm (54.3 by 47.6 by 25.6 inches)
Weight
Standard version with rechargeable battery pack and clip: 610 g (21.5 oz.)
Standard version with alkaline battery pack and clip: 620.5 g (21.9 oz.)
Wireless version with rechargeable battery pack and clip: 692.5 g (24.4 oz.)
Wireless version with alkaline battery pack and clip: 705 g (24.9 oz.)
Operating Temperature
Alkaline battery: -20°C to +50°C (-4°F to 122°F)
Rechargeable battery: -40°C to +60°C (-40°F to 140°F) (just for 20 minutes at -40°C)
LEL performance temperature range: -30°C to +55°C (-22°F to 144°F)
Accuracy specification of combustible gas performance
Allowed indication deviation is ± 3% of full scale concentration from 0°C and 40°C.
Allowed indication deviation is ± 5% of full scale concentration from -25°C to 0°C and from +40°C
to +55°C.
Allowed indication deviation is ± 10% of full scale concentration from -30°C to -25°C.
Storage Temperature
-20 C to +65 C (-4°F to +149°F)
Operating Humidity
20% to 90% relative humidity continuous, 0% to 95% relative humidity intermittent
Dust and Moisture Ingress
IP 65; IP66 with flow adapter in place