User Manual

ImpactXtreme Operator’s Manual 8 March 2013
Charge the Rechargeable Battery in a Deactivated Detector
Charge the battery in a normal atmosphere (20.9% O
2
) that is free of hazardous gas. To avoid
personal injury and/or property damage, adhere to the following warnings and cautions:
Charge the battery after each work day.
Charge the battery immediately when the detector emits a low battery alarm.
Charge the battery in a safe area that is free of hazardous gas in temperatures ranging
from 0°C to 40°C (32°F to 104°F).
Charge the battery using BW Technologies by Honeywell charger adapters designed for
the ImpactXtreme only. Do not use any other chargers or adapters. Failure to adhere to
this caution can lead to fire and/or explosion.
The charging adapter is voltage specific to your region. Using the charging adapter
outside your region will damage the charger and the detector.
The ImpactXtreme uses a lithium battery (IX-BAT-R1) that may present a risk of fire or
chemical burn hazard if misused. Do not disassemble. Do not heat above 100°C (212°F).
Do not incinerate.
Lithium polymer cells exposed to heat at 130°C (266°F) for 10 minutes can cause fire
and/or explosion.
When replacing the battery, use only approved lithium polymer cells supplied by BW
Technologies by Honeywell or an authorized dealer. Use of any other cell can cause fire
and/or explosion. For more information, refer to Replacement Parts and Accessories.
Dispose of used lithium cells immediately. Do not disassemble and do not dispose of in
a fire. Do not mix with the solid waste stream. Spent batteries must be disposed of by a
qualified recycler or hazardous materials handler.
Keep lithium cells away from children.
Refer to the ImpactXtreme Cradle Charger Operator’s Manual
The detector will not detect gas while in charging mode.
The wireless model will not communicate with Location Manager while in charging
mode.
Remove the tubing from the pump adapter before inserting the detector into the cradle
charger.
Before you begin
1)
Move to a normal atmosphere (20.9% O
2
) that is free of hazardous gas. Do not charge the
battery in a hazardous area.
2)
In normal operating mode, press and hold for 3 seconds to deactivate the detector.