i Important information
It is advised to take a photo of the system prior to covering.
7. Read system resistance (2
nd
time) in accordance with Section 5.
8. Covering
Prior to covering check the fixing of the thermostat’s floor sensor (as in Section 3.).
9. Read system resistance (3
rd
time) in accordance with Section 5.
10. Placing the cover
Place the cover in accordance with the instructions provided by the producer.
11. Connection of the thermostat and electricity
Assign an electrician to carry out electricity and thermostat connection. Following connection, read the
resistance for the last time, and record the values on the Warranty card. See Section 13.
Note: Mark the circuit-breaker of the heating system on the switch board.
12. Read system resistance (4th, last time) in accordance with Section 5.
13. Documentation
Fill-out the Warranty card of both the heating mat and the thermostat right after installation. Failing to
do so may result in losing warranty rights. For detailed Warranty terms and conditions se the product’s
Warranty card.
i Important information
Keep the Warranty card for any later warranty issues.
14. Activation of the BVF L-PRO heating mat
After installing the laminate floor cover the system is ready for use. Turn it on and set the desired temper-
ature on the thermostat according to the user manual. Step-by-step heating-up of the system is advised,
particularly when heating-up for the first time.
5 REGISTRATION OF READ VALUES
i Important information
To ensure the validity of the 10 years extended warranty period, carry out the following resistance read-
ings and record the values on the Warranty card of the product. Do not lose the warranty card.
Registration of insulation and resistance reading values are required four times during the installation.
(See Section 4.5)
5.1 Reading insulation resistance
By reading insulation resistance you can make sure that the cable’s electric insulation is not damaged.
1. Connect the grounding’s connection to the black
lead of the measuring device and connect the
other two to the red cable simultaneously.
2. The measuring device shall read “open” or in-
finite value. In case of different values turn to
the distributor of the product.
3. Record the read data on the product’s Warranty
card.
5.2 Reading heating mat resistance
1. Select range 200-2.000 ohm on the device.
2. Connect the device’s leads to the brown and blue
connections.
3. Compare the read values with the data given
in the table. Maximal allowed variance shall be
between -10% and +10%. Should you notice
a different value, contact the distributor of the
product.
4. Record the read data on the products Warranty
card.
i Important information
Carry out the resistance reading of the NTC floor sensor of the thermostat prior to both placing and