User Manual
Figure 4- PAR4003 / PARM4003
4
*holds application in position when air is disconnected
Model
Number
Use w/
Cylin-
der
Usable
Oil
Capacity
(gal)
Motor
Size
(HP)
Pressure
Rating
(psi)
Oil Output
Flow Rate
(in )
Valve
Type
Valve
Function
Air
Pressure
at rated
capacity
(psi)
Air Con-
sumption
at rated
capacity
(cfm)
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
PARD4001
Single
Acting
1
4
600 10,000
465
70
Dump *Advance/
Return
100
95
PARD4003
3
PAR4003
512
PW3
Manual Advance/
Hold/Re-
turn
PARM4003 Double
Acting
PW4
Manual
3
PRODUCT SPECIFICATIONS
Model
Number
Sound
Level
(dBA)
Dimension (in) Weight
(lbs)
A B C D E F G
PARD4001
**100
19.10 11 5.79 4.72 8.07
12.34
16.34 44
PARD4003 - 13.56 8.35
7.28
12.01
18.4 51
PAR4003
13.55
10.53
8.21
18.52
50
PARM4003
Figure 3- PARD4001
!
**This device operates at 100 decibels!
Regular exposure to 90 decibels can
cause ear damage! Always wear hearing
protection when operating or near this
equipment.
3/8"-18NPTF(2X)
A
B
C
D
E
F
G
3/8"-18NPTF(2X)
A
B
C
D
E
F
G