Owner Manual

POWER SUPPLY
Your fridge must be connected to a stable and regulated 12 V or 24 V DC
power supply only. The compressor will automatically detect which voltage is
present adjust accordingly.
If you are using a generator or other power supply, the output must be a pure
sine wave. Any fluctuations in generator current may damage the compressor.
WIRING
For optimum results, you will need the correct sized wire depending on the
distance from your power supply to the fridge. Wiring must be directly from
your fridge to your battery and should be continuous without joins. Please also
ensure the earth is wired directly to your battery, not to a chasse. If your wiring
is insufficient, your fridge may not perform correctly or may be even be
damaged.
CROSS SECTION
IN MM2
MAXIMUM LENGTH OF WIRE IN METRES
12 V
24 V
2.5
2.5
6
4
4
8
6
6
12
10
10
20
Any switches must have a breaking load not less than 20 A on 12 V or 10 A on
24 V.
The power supply wiring must also be protected with a 15 A fuse.
Ensure sure the wiring polarity is correct. Connect the red wire to the positive
terminal (+) and the black wire to the negative terminal (-).
Never connect bare electric wires. Use only connections of a size suitable for
the cross section of the wire being used.