BushmanDC-X Owners Manual

11
RED LED ERROR LIGHT
From mid 2021 onwards all Bushman DC-X series are fitted with a red LED error light.
Mid 2021 mid 2022 the red LED is located on the compressor module.
Mid 2022 onwards the red LED is located inside the interior light housing.
The number of flashes corresponds to the following error type.
ERROR CODE
BATTERY PROTECTION CUT-OUT
The voltage is outside the cut-out setting. [LOW VOLTAGE]
TOO MAY START ATTTEMPTS (OR FAN OVER CURRENT)
This generally indicates the compressor has had too many start attempts due to battery
protection cut-out. [LOW VOLTAGE]
It could also indicate fan overload of more than 0.5A but this is extremely rare.
MOTOR START ERROR
The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)
MINIMUM MOTOR SPEED ERROR
Refrigeration system is overloaded, and motor cannot maintain minimum speed (1850 rpm)
THERMAL CUT-OUT
Refrigeration system overloaded or ambient temperature is too high.
TECHNICAL SPECIFICATIONS
DC50-X
DC65-X
DC85-X
DC130-X
Secop
BD35
Secop
BD35
Secop
BD35
Secop
BD35
12 V / 24 V
DC
12 V / 24 V
DC
12 V / 24 V
DC
12 V / 24 V
DC
60 W
60 W
60 W
60 W
W 380
D 495
H 525
W 450
D 515
H 525
W 475
D 550
H 625
W 525
D 550
H 750
16.4 kg
18 kg
22.5 kg
27.2 kg