DC-X Owners Manual

5
ADJUSTING THE DOOR LATCH
Whenever the door or hinges have been moved, please adjust the top metal rail that the door latch clips under.
Loosen the screws and move the top metal rail towards the rear of the fridge cabinet until the plastic door latch just
makes light contact. If there is more than 1mm of movement, this will need adjusting.
See diagram below:
CORRECT 0-1MM GAP INCORRECT 2MM+ GAP
RUBBER DOOR SEALS
1. It is important that the rubber door seals are making contact 100% of the way around the fridge cabinet.
2. There are magnets inside the rubber seal which pull towards the metal fridge cabinet to keep it airtight.
3. After you have adjusted your door latch, check to see that the rubber seal is making contact with the fridge
cabinet on all 4 sides. If there is even a small gap, this will affect the performance of your fridge.
4. Starting from a corner, gently heat up the rubber seal with a hair dryer or light heat from a heat gun (be careful
not to overheat the rubber or it will melt). As the rubber heats up, the magnets inside will pull the seal towards
the fridge cabinet. Slowly work your way along the rubber from one corner to the other until it is fully sealed.