DC-X Owners Manual
11
RED LED ERROR LIGHT
From mid 2021 onwards all Bushman DC-X series are fitted with a red LED error light.
• Mid 2021 – mid 2022 the red LED is located on the compressor module.
• Mid 2022 onwards the red LED is located inside the interior light housing.
The number of flashes corresponds to the following error type.
NO. OF
FLASHES
ERROR CODE
1
BATTERY PROTECTION CUT-OUT
The voltage is outside the cut-out setting. [LOW VOLTAGE]
2
TOO MAY START ATTTEMPTS (OR FAN OVER CURRENT)
This generally indicates the compressor has had too many start attempts due to battery
protection cut-out. [LOW VOLTAGE]
It could also indicate fan overload of more than 0.5A but this is extremely rare.
3
MOTOR START ERROR
The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)
4
MINIMUM MOTOR SPEED ERROR
Refrigeration system is overloaded, and motor cannot maintain minimum speed (1850 rpm)
5
THERMAL CUT-OUT
Refrigeration system overloaded or ambient temperature is too high.
TECHNICAL SPECIFICATIONS
DC50-X
DC65-X
DC85-X
DC130-X
COMPRESSOR
Secop
BD35
Secop
BD35
Secop
BD35
Secop
BD35
VOLTAGE
12 V / 24 V
DC
12 V / 24 V
DC
12 V / 24 V
DC
12 V / 24 V
DC
WATT RATING
60 W
60 W
60 W
60 W
EXTERNAL
DIMENSIONS
(mm)
W 380
D 495
H 525
W 450
D 515
H 525
W 475
D 550
H 625
W 525
D 550
H 750
NETT WEIGHT
16.4 kg
18 kg
22.5 kg
27.2 kg