Installation Instructions
11
Figure 11
Figure 12
Adjusting The Reduced Flame Position:
The flame length in the minimum position is adjusted
with a flat screw located on the valve. For valves with
FFD, the screw is located on the side of the valve
spindle. For valves without FFD, the screw is located
inside the valve spindle. For easier reduced flame
adjustment, we advise to remove the control panel
(and microswitch, if present) during adjustment.The
position the by pass screw must be loosened in
transformation from LPG to NG. In transformation
from NG to LPG, the same screw must be fastened.
Make sure that the appliance is unpluged from the
electric current and the gas feed is open.
To determine the min. position, ignite the burners and
leave them on in minimum position. Remove the knobs
because the screws are accesible only when the knobs
are removed.
Changing the gas inlet:
For some countries, the gas inlet type can be different
for NG/LPG gases. In such a case, remove the
current connection components and nuts (if any) and
connect the new gas supply accordingly. In all
conditions, all components used in gas connections
should be approved by local and/or international
authorities. In all gas connections, refer to the
“ASSEMBLY OF GAS SUPPLY AND LEAKAGE
CHECK” clause explained before.
Installation of your oven
Figure 13
Figure 14
With the help of a small screwdriver fasten or loosen the
by pass screw around 90 degrees. When the flame has a
length of at least 4mm, the gas is well distributed. Make
sure that the flame does not die out when passing from
the maximum position to the minimum position. Create
an artificial wind with your hand toward the flame to see if
the flames are stable. For oven burner, operate the oven
burner at min. position for 5 minutes, then open and
close the oven door for 2-3 times to check the flame