Instruction manual
Appliances 9
Touring - 03/11-1 - englisch (EN) - 0731070 - HYW-0102-01EN 87
9.2.2 Heater (Variant 1)
Turning on:
Open the regulator tap on the gas bottle and
the gas isolator tap "Heater".
Turn control knob (Fig. 69) on the heater to
the required position and press it firmly.
The automatic ignition produces ignition
sparks. A clicking noise can be heard.
Keep the control knob pressed until there is
a flame. Press down for another 10 seconds
to activate thermocouple.
Fig. 69 Heater control knob
Turning off:
Turn the control knob (Fig. 69) on the heater to "0". The automatic ignition is switched off simul-
taneously.
If the heating is not to be used for an extended period, close the main regulator tap on the gas
bottle and the "Heater" gas isolator tap.
> In case of problems wait for two
minutes before trying again.
> The automatic ignition sparks until the gas ignites. If there is no gas, it will continue to
spark until the battery feeding it is empty. When the heating is not required, set the
control knob to "0" to avoid the battery running flat.
> If the clicking noise cannot be heard at all or only in intervals of several seconds during
ignition: change the battery.
> Further information can be obtained from the separate "TRUMA gas heater" instruc-
tion manual.