Instruction manual
Electrical Fittings 8
Touring - 03/11-1 - englisch (EN) - 0731070 - HYW-0102-01EN 79
Turn on the external charger.
See the instructions for use of the connected charger for information concerning charge period
required for the battery.
Disconnect the external charger in reverse order.
8.7 Living Area Battery in the Winter
If the caravan has not been operated for some time or the 240 V power supply has not been con-
nected for some time, the living area battery will quickly lose its capacity at low outside temperatures.
If the caravan is laid up for a long time in winter, remove living area battery and store in a frost-pro-
tected room so that it will not freeze and will be destroyed.
8.8 Fuses
The appliances connected to the 12 V supply in the caravan are fused individually. The fuses are
accessible on the power pack (Fig. 58 or Fig. 59). Function, value/colour of the relevant fuses are
given in the following table. When changing fuses, only use fuses with the specified values.
8.8.1 Fuse Rating on the Power Pack
Only replace defective fuses when the cause of the defect is known and has been
remedied.
Never bridge or repair fuses.
No. Function Colour Current
1 Awning light 12 V Light brown 5 A
2 Water pump bar and toilet, fan heating Brown 7.5 A
3 Light 12 V bar, front seating group, toilet; socket 12 V
bar
Red 10 A
4 Light 12 V rear seating group; sockets 12 V cabinet, bar,
rear seating group
Red 10 A
5 Refrigerator 12 V Blue 15 A
6 Battery main fuse (Power Pack SE) Blue 15 A