Instruction manual
Electrical Fittings 8
Touring - 03/11-1 - englisch (EN) - 0731070 - HYW-0102-01EN 77
8.5 Energy Reserve of the Living Area Battery
The capacity of a battery is limited as to time. The higher the number of electrical appliances, the
faster the energy of the living area battery is consumed. A battery which has been installed for years
has no longer the complete capacity available.
To protect the living area battery, no more than 80 % of the battery’s capacity should be drawn.
Therefore, a regular check of the charging condition of the living area battery is recommended.
Balance of energy consumption (example)
*) Estimated operating hours
Balance of
energy
Summer Winter
Output Cur-
rent
Hrs/
day*
Output/
day
Current/
day
Hrs/
day*
Output/
day
Current/
day
1 Seating
group
20 W 1.7 A 1 20 W 1.7 Ah 2 40 W 3.4 Ah
2 Kitchen 18 W 1.5 A 1 18 W 1.5 Ah 2 36 W 3 Ah
3 Bathroom
unit
30 W 2.5 A 1 30 W 2.5 Ah 1 30 W 2.5 Ah
4 Water pump 18 W 1.5 A 0.5 9 W 0.8 Ah 0.5 9 W 0,8 Ah
5 Front lights 20 W 1.7 A 0.5 10 W 0.8 Ah 1 20 W 1.7 Ah
6Trumatic S
3002 heater
12 W 1 A 16 192 W 16 Ah
7 Television
with receiver
40 W 4.2 A 2 80 W 8.4 Ah 4 160 W 17 Ah
8 Awning light 10 W 0.8 A 1 10 W 0.8 Ah 1 10 W 0.8 Ah
Total 177 W Approx.
16.5 Ah
Total 497 W Approx.
45.2 Ah
Approx. 2.4 days "power" (in-
dependent)
Approx. 0.9 days "power" (in-
dependent)