Instruction manual

14 Fault Search
136 Touring - 03/11-1 - englisch (EN) - 0731070 - HYW-0102-01EN
14.6.3 Refrigerator
14.7 Water Supply
Fault Cause Remedy
Refrigerator does not switch
on when operating in 240 V
mode
240 V automatic circuit break-
er switched off
Switch on 240 V automatic cir-
cuit breaker
Fuse on the power pack is de-
fective
Replace fuse
Refrigerator does not switch
on when operating in 12 V
mode
Contacts on the plug and/or in
the socket have oxidised
and/or are contaminated
Clean contacts and spray with
contact spray
Short circuit caused by water
in the plug and/or socket
Open plug and/or socket, dry
out, and spray with contact
spray
Cable interruption on the plug
and/or socket
Open plug, re-connect if nec-
essary (see chapter 8)
Fault Cause Remedy
Leakage water inside the
vehicle
A leak has occurred Identify leak, re-connect sup-
ply tubes
No fresh water Fresh water canister or fresh
water tank is empty
Fill with fresh water
Drain cock not closed Close the drain cock
Pump is defective Exchange pump (have it ex-
changed)
Fuse on the power pack is de-
fective
Replace fuse
Hose is kinked Straighten hose or replace
Power pack is defective Contact ERIBA customer
service
Thetford toilet does not have
any flush water
Fresh water canister or fresh
water tank is empty
Fill with fresh water
Fuse in Thetford cassette is
defective
Replace fuse
Waste water tank cannot be
emptied
Drain cock is clogged Open the cleaning cap on the
waste water tank and drain
the waste water. Rinse the
waste water tank well