Instruction manual
14 Fault Search
134 Touring - 03/11-1 - englisch (EN) - 0731070 - HYW-0102-01EN
14.5 Cooker
14.6 Hot Water Source, Boiler, Refrigerator
In the event of a defect occurring on the refrigerator, hot water source or boiler contact the nearest
customer service workshop of the relevant appliance manufacturer. The list of addresses is en-
closed with the accompanying appliance documentation. Repairs to the refrigerator or heater or boil-
er may only be carried out by qualified personnel.
14.6.1 Truma Hot Water Source
Fault Cause Remedy
Ignition fuse does not operate
(flame does not burn after the
control knobs are released)
Heat-up time is too short Keep control knob pressed for
approx. 15 to 20 seconds after
ignition
Ignition fuse is defective Contact ERIBA customer
service
Flame extinguishes when be-
ing reduced to its minimum
setting
Thermocouple sensor is incor-
rectly set
Correctly reset thermocouple
sensor (do not bend). The
sensor tip should protrude by
5 mm beyond the burner. The
sensor neck should not be
more than 3 mm away from
the burner ring; if necessary,
contact ERIBA customer serv-
ice
Fault Cause Remedy
The hot water source is con-
nected to power supply but
does not heat
Operating switch is switched
off
Switch on the operating
switch, the indicator lamp on
the switch must light up
Operating switch defective Contact ERIBA customer
service
240 V automatic circuit break-
er switched off
Switch on 240 V automatic cir-
cuit breaker
240 V power supply discon-
nected
Connect 240 V power supply
Heating coil of the hot water
source is defective
Contact ERIBA customer
service