Instruction manual
262 T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Technical data
16
Charging current distribu-
tion at mains connection
Starter battery float charge
with max. 2 A
max. 2 bar
Living area battery charge
with max. 18 A
max. 18 A
Charging current distribu-
tion during the journey
Simultaneous charging of
starter and living area bat-
teries by means of the alter-
nator
50 A
Parallel battery switching
via disconnector relay
Maximum permitted alter-
nator charging current to
the living area battery: 50 A
(see block diagram)
Battery monitor Disconnection 10.5 V ± 0.1 V
Battery monitor Minimum voltage for con-
nection
11.0 V ± 0.1 V