Instruction manual

246 T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Troubleshooting
14
14.9.1 Dometic 8 series
Z In the event of a fault, the "Fault" indicator lamp will always light up as well
and an acoustic signal will sound for about 20 seconds.
Fault Cause Remedy
LED " " flashes No 230 V power supply Connect the 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
230 V operating voltage
too low
Have the 230 V power
supply checked by an au-
thorised specialist work-
shop
LED " " flashes Fuse on the transformer/
rectifier is defective
Replace fuse on the
transformer/rectifier
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V operating voltage
too low
Have the 12 V power
supply checked by an au-
thorised specialist work-
shop
No D+ signal Contact customer service
LED " " flashes
1)
1)
After fixing the issue, press the illuminated button for "Fault"/"Reset".
Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Cobwebs or burnt resi-
due in the burning cham-
ber
Remove the ventilation
grill on the outside of the
vehicle and clean the
burning chamber
LEDs for display of the
temperature range flash
Temperature sensor de-
fective
Contact customer service
LED " " and LEDs for
display of the tempera-
ture range flash
230 V heater element de-
fective
Contact customer service
LED " " and LEDs for
display of the tempera-
ture range flash
12 V heater element de-
fective
Contact customer service
LED " " and LEDs for
display of the tempera-
ture range flash
Faulty burner or power
unit
Contact customer service
Refrigerator does not re-
frigerate sufficiently
Insufficient ventilation of
unit
Check if ventilation grills
are covered; remove cov-
ers if necessary
Remove ventilation grills
and clean the space be-
hind them (of leaves etc.)
Ambient temperatures
are too high
Remove the ventilation
grills periodically