Instruction manual
240 T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Troubleshooting
14
14.4 Fuel cell
14.5 Gas system
12 V indicator lamp does
not come on
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Starter or living area bat-
tery is not charged
Charge the starter or liv-
ing area battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Flat fuse (2 A) in the liv-
ing area battery is defec-
tive
Replace flat fuse (2 A) in
the living area battery
Extractor hood does not
work
230 V automatic circuit
breaker is switched off
Switch on the 230 V au-
tomatic circuit breaker
Fuse (15 A) at the trans-
former/rectifier is defec-
tive
Replace fuse (15 A)
Extractor hood defective Contact customer service
Z Do not open the fuel cell. The fuel cell contains no parts that could be
repaired by itself.
Z All faults are not displayed. If the faults cannot be rectified using the fol-
lowing table or the instruction manual for the fuel cell, please contact the
customer service.
Fault (display) Cause Remedy
Fuel cell cannot be
switched on
No battery connected,
battery connected incor-
rectly or totally dis-
charged
Inspect the connection
Fuse is defective Replace fuse; if it hap-
pens again, contact the
customer service
Failure: Environment too
warm
Ambient temperature too
high (40 °C)
Fuel cell restarts when
the ambient temperature
is between 0 °C and
40 °C
X In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
X If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
X Have the defective gas system repaired by an authorised specialist
workshop.
Fault Cause Remedy