Instruction manual
211T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Care
11
11.4.3 Cleaning the water pipes
Empty the water system.
Close all drain holes and drain cocks.
Fill mixture of water and cleaning agent into the water tank. Observe the
manufacturer's instructions regarding the mixing ratio.
Open the drain cocks one by one.
Leave the drain cocks open until the mixture of water and cleaning agent
has reached the respective drain.
Close the drain cocks.
Set all the water taps to "Hot" and open them.
Leave the water taps open until the mixture of water and cleaning agent
has reached the drain.
Set all water taps to "Cold" and open them.
Leave the water taps open until the mixture of water and cleaning agent
has reached the drain.
Close all water taps.
Flush the toilet several times.
Allow the cleaning agent to act in accordance with the manufacturer's
instructions.
Empty the water system. Collect the mixture of water and cleaning agent
for correct disposal.
For rinsing fill the entire water system with drinking water and empty again
several times over.
11.4.4 Disinfecting the water system
When disinfecting the water system, proceed the same way as when cleaning
the water pipes (see section 11.4.3). Simply use disinfectant instead of
cleaning agent.
Z Only use suitable cleaning agents as sold by the specialist trade.
Z The cleaning agent must meet national regulations and be approved (if
required).
Z Collect any emerging mixture of water and cleaning agent for correct dis-
posal.
Z Only use suitable disinfectants as sold by the specialist trade.
Z The disinfectant must meet national regulations and be approved (if
required).
Z Collect any emerging mixture of water and disinfectant for correct disposal.