9
If there is a fault in the energy source that is set, the system switches to the
next available energy source. If no other energy source is available, the oper-
ating indicator flashes and an error code appears on the display.
230 V operation If the 230 V power supply is connected, this energy source is selected as the
first priority by the SES.
12 V operation 12 V operation is only selected by the "SES" if the vehicle's engine is running
and the alternator supplies sufficient 12 V operating voltage.
Gas operation
If the 230 V power supply is disconnected and the vehicle's engine is not run-
ning the "SES" selects the gas supply. When selecting gas operation the igni-
tion fuse is opened automatically so gas can get into the burner. At the same
time the electronic ignition is activated. If the gas flame is extinguished, e.g. by
blast of wind, the ignition is activated immediately and re-ignites the gas.
Change-over between
energy sources
When changing over between the different energy sources there are forced
delays built in the "SES". This means, that after a change-over to a new energy
source the refrigerator can not be operated immediately. When changing over
from 12 V operation to gas operation, a 15-minute delay is built in the SES.
This prevents a change-over to gas operation when the vehicle is stopped
briefly and the engine is switched off (e.g. stop to fill tank).
Fig. 230 Operating controls for the
refrigerator (Thetford with
SES)
1 Operating mode button
2 Display
3 Operating indicator (blue)
4 On/Off button
5 Temperature selection button
X Never let gas escape unburned due to danger of explosion.
Z Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
X Open flames are prohibited at petrol stations. If the stop takes longer
than 15 minutes, the refrigerator has to be turned off at the On/Off