Instruction manual

149T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Electrical system
8
Replacing the fuse on the
solar charge regulator
200 W:
Disconnect all 12 V appliances.
Replace flat fuse 15 A/blue (Fig. 183,1).
8.10.2 230 V fuse
A fault current protection switch (FI-switch) (Fig. 184,4) in the fuse box
(Fig. 184,3) protects the complete vehicle from fault current (0.03 A).
The downstream safety cut-out (10 A) (Fig. 184,2) secures the 230 V sockets,
the power supply unit, the auxiliary charging unit and the refrigerator.
For vehicles with special equipment, e.g. air conditioning unit, an additional
safety cut-out (16 A) (Fig. 184,1) secures the device.
Position See chapter 16.
Checking fault current
protection switch:
When the vehicle is connected to the 230 V power supply, press the test
button (Fig. 184,5). The fault current protection switch (RCD) must be acti-
vated.
Z Check the fault current protection switch for each connection to the 230 V
power supply, at least once every 6 months.
Fig. 184 230 V fuse box with safety cut-
out and FI-switch