Instruction manual
134 T-Modell - 13/14 - Ausgabe 08/13 - 2354677 - BUE-0029-14EN
Electrical system
8
z The transformer/rectifier distributes the current to the 12 V circuits and
secures them. Devices with a maximum of 10 A can be connected to the
sockets.
z The transformer/rectifier provides connections for a solar charge regulator,
an auxiliary charging unit, as well as other control and monitoring functions.
z When the engine is turned off, the transformer/rectifier separates the
starter battery electrically from the living area battery. This prevents the
12 V living area appliances from discharging the starter battery.
z The battery cut-off switch in the transformer/rectifier separates all the appli-
ances from the living area battery.
The transformer/rectifier only works in conjunction with a panel.
The power in the transformer/rectifier (> 18 A) is divided into charging current
and current to the appliances. The charging current is always just the portion
that is not being used by any appliances. If the current to the appliances
exceeds the current available, then the living area battery is discharged.
Position See chapter 16.
8.5.1 Battery cut-off switch
The battery cut-off switch switches off all the appliances in the living area,
even inactive ones. Even appliances such as the entrance step, basic lighting
or the refrigerator will stop working. This prevents the living area battery from
slowly discharging if the vehicle is not used for a longer period of time (e.g.
temporary lay-up).
If the vehicle is connected to the 230 V power supply, the batteries can then
be charged from the transformer/rectifier, even if the battery cut-off switch is
switched off.
This also applies for charging via a solar installation or fuel cell.
8.5.2 Battery selector switch
8.5.3 Battery monitor
The battery monitor in the transformer/rectifier monitors the voltage in the
living area battery.
If the battery voltage falls below 10.5 V, the battery monitor in the transformer/
rectifier switches off all the 12 V appliances.
X If the battery selector switch is set incorrectly, there is the danger of the
formation of detonating (oxy-hydrogen gas). Danger of explosion!
Z Incorrect setting of the battery selector switch damages the living area bat-
tery.
Z The factory settings of the battery selector switch must not be changed.
Z You must fully recharge a discharged living area battery as soon as pos-
sible.