Installation guide

26
Carefully install Dome Middle Sides (TFS/OFS 63-8) as
shown in Figure 50.
Figure 50
TFS/OFS 63-8
Dome Middle Side
TFS/OFS 63-8
Dome Middle
Side
TFS/OFS 63-10
Dome Middle
As you are connecting each Burntech® component, be
certain you are following the instructions given previously
for using Burntech® mortar. Stop to look at the smoke
dome side, front and rear walls to see that they are aligning
correctly and that the surfaces are smooth and uniform.
Make sure connections are covered with an adequate
amount of mortar. Remember that you have the option
of using shims but they must be removed and any holes
lled. Make any adjustments to the replace alignment
before continuing to the next step.
Assemble Upper Domes (TFS/OFS 63-11) and Dome Sides
(TFS/OFS 63-7) as shown in Figure 51. Check your
assembly here. If things are proceeding as they should
be, the nished top surface should be at and level.
Figure 51
TFS/OFS 63-9
Dome Top
TFS/OFS 63-7
Dome Side
TFS/OFS 63-11
Upper Dome
35.
36.
37.
Finally, set the Dome Top (TFS/OFS 63-9) into position.
Be sure that it is ush in every direction as you place it on
the crest of the smoke dome wall assembly.
Note that the chimney hole on the Dome Top is not centered
from front to back - it should be offset closest to the rear of the
replace. A marker on the Dome Top indicates the front (see
Figure 52).
Figure 52
Center of Ø16” chimney hole
is offset towards the rear.
10”
12-1/2”
TFS/OFS -63
Now that you have completed the smoke dome assembly,
all the components should stack up for a smooth transition
into the ue components. Setting the smoke dome
completes the Burntech® Firebox and Smoke Dome
assembly. You are now ready to begin the installation of
the necessary re brick lining and the ue components.
WARNING: DO NOT PACK REQUIRED AIR SPACES
WITH INSULATION OR OTHER MATERIALS.
For use of Masonry Chimney sections on the Burntech®
replaces, please see Masonry Chimney instructions
located online at www.Burntech®.com
38.
39.
40.
TFS/OFS-63 Fireplace Assembly
Figure 53
Burntech®
Masonry Chimney
Rebar into Dome Top:
See Supplemental
Installation Guide for
Chimney reinforcement
instruction.
Check with local codes for use of Masonry Chimney in
your area - restrictions may apply.