Brochure

V9SERIES
HOTWATER
ORSTEAM
BOILER
Maximum
water
working
Pressure:7o
P5l
water,
15 PSI Steam
The
commercial
equipped
with either
steam or water
trim
and controls. The
product
is
energy efficient with
a combustion
efficiency
of up to 84o/o. All
sizes
exceed the efficiency
requirements
of ASHRAE
90.1.
The
bond that
makes the
difference.
Each
V9
boiler section is
hvdro-
statically
tested
at two
and one half
times rated
working
pressure
to
make
sure that
the section is
fl
awless.
Factory-assembled
sections
are tested
at one
and one
half
times
the
rated
working
pressure.
The
sections
are surface
ground
to
insure
smooth
surface
mating,
and
sealed
gas-tight
with
an
elastic sealing
compound.
This
sealant is
used
on all section
joints
to
guarantee
a completely
sealed
and
gas-tight
assembly required
for
forced
draft operation. The
sealant
is
easily
applied and
takes less
time
than
applying conventional
gasket
materials
and lasts many
times longer.
Each
section
is
then
joined
with
quality
cast iron nipples
which will
boiler
that
fits the
lncrease
the
longevity
of the
boiler by
resisting
petroleum
based
chemicals,
including
antifreeze
which
can deteriorate the
gaskets
used in some
competitors' boilers.
Time-proven cast iron
nipples last
the life of
the boiler. They expand
and
contract along with
the sections
they
join
ensuring the integriry
of
the
entire section assembly.
Added
safety and
system
longev-
ity are
achieved with the
addition of
a
pressure
relief
door as standard
equipment. This will reduce
poten-
tial damage to the
breeching or heat
exchanger
in
the event
of an
inadvertent
delayed ignition
of the
burner.
CAD/CAE
speeds,
verifies
boiler
design
The V9 is
the firsr
of its
kind
because
it was
designed
completely
on
computers
to optimize
efficiency
and
minimize
space requirements.
CAD/CAE
perfects
the design
while
improving
quality.
By modeling
the boiler
on com-
puters,
Burnham
engineers
were
quickly
able
to see the
effects
of
every design
decision
from
exact
configuration
of the heat
transfer
surface
to the location
of
combus-
tion
passageways.
Such simula-
tions
permit
design
optimization
without
costly
testing
and re-testing
of different
prototypes.
Specifying
a heating
system
in
CSI
(Construction
Specifications
Institute)
format is
made
easy
with
Burnham'
s
Smartspec
computer
sofrware
program.
Use
the
program
menu
to specify
atmospheric
or
forced
draft;
steam
or hot water;
gas,
oil.
or combination
fuels;
single or lead-lag;
knockdown
or
packaged;
and output ratings
in
gross,
net or
square feet
of steam.
Optional
equipment
menu
and
built-
in
editing features
let
you
create
a
customized
CSI specification.
Consult
your
local
Burnham
sales
representative
for details.
Commitment
to
quality
For
all
your
boiler needs
look
to
Burnham.
Burnham has
over 100
years
experience
producing
residen-
tial and
commercial
boilers.
Our
continuing
commitment
to
quality
and
excellence has
made
us
America
s Boiler
Company.
job.
The
Burnham@ V9
Series cast
iron
boiler represents
one
of the
finest
designs in
commercial
boilers.
The V9 is
quality
through
and
through. It is
a wet base, forced
draft design which
means
there
is
no
need for
a special base and
combustion
chamber or mechanical
equipment
to artificially induce
proper
draft. Because
the boiler is
a
forced
draft unit, it
provides
optimum draft for
controlled
combustion, thus
eliminating the
need for high
chimneys. And with
a
rear
smoke
outlet, the V9 requires
only six and one half feet
of vertical
clearance from floor
to ceiling.
The
sectional construction
of the
V9
boiler
makes it
ideal for
use
in
installations
where
the boiler room
is not
easily accessible.
In
addition to being
shipped as
individual
sections the boiler is
available with factory-assembled
sections or as
a completely
pack-
aged unit. The
packaged
unit is
fastened
to a steel skid to facilitate
lifting
with
a
fork
truck or crane
and
will fit
through
a standard 56 x
80
inch
doorwav. The
skid can
serve as the
boiier
foundation,
replacing
the need for a
concrete
pad.
A factory fire-test is
available
on all
packaged
units.
All regular
maintenance
access
areas are located
on the left
side
allowing
the
V9
boiler to be in-
stalled 9" from
the right sidewall.
The
tankless
hot
water heaters
provide
ratings
of 6.0 to 28.5
GPM
and
are also accessed from
the left
side of the boiler.
Available in
ten sizes with
gross
output ratings from
377 to 1445
MBH,
the V9
Series
fires
gas,
oilor
combination
gas/oil
and can be