Figure 8: Baffle Orientation in Flueways
Step a. Install stainless steel baffles provided in 
miscellaneous parts carton as follows, refer to 
Table 3 and Figure 8:
•    Model MPO-IQ84B - To install flueway baffle 
in 2
nd
 pass on left side of boiler, hold baffle 
with word "Left" readable at the top. Slide 
baffle in flueway until position tab touches 
fins on left side of 2
nd
 pass flueway. To install 
flueway baffle in 2
nd
 pass flueway on right 
side of boiler, hold baffle with word "Right" 
readable at the top. Slide baffle in flueway 
until position tab touches fins on right side 
of 2
nd
 pass flueway.
•  Model MPO-IQ115B - To install flueway baffle 
in 3
rd
 pass on left side of boiler, hold baffle 
with word “Left” readable at the top. Slide 
baffle in flueway until position tab touches 
fins on left side of 3
rd
 pass flueway. To install 
flueway baffle in 3
rd
 pass flueway on right 
side of boiler, hold baffle with word “Right” 
readable at the top. Slide baffle in flueway 
until position tab touches fins on right side 
of 3
rd
 pass flueway. To install flueway baffle 
in 2
nd
 pass on left side of boiler, hold baffle 
with word “Left” readable at the top. Slide 
baffle in flueway until position tab touches 
fins on left side of 3
rd
 pass flueway. To install 
flueway baffle in 2
nd
 pass flueway on right 
side of boiler, hold baffle with word “Right” 
readable at the top. Slide baffle in flueway 
until position tab touches fins on right side 
of 3
rd
 pass flueway.
  To install combustion chamber ring, set ring in 
the front section of the combustion chamber.
•    Models MPO-IQ147B thru MPO-IQ231B - To 
install flueway baffle in 2
nd
 pass flueway on 
left side of boiler, hold baffle with word "Left" 
readable at the top. Slide baffle in flueway 
until position tab touches fins on right side 
of 2
nd
 pass flueway. To install flueway baffle 
in 2
nd
 pass flueway on right side of boiler, 
hold baffle with word "Right" readable at the 
top. Slide baffle in flueway until position tab 
touches fins on left side of 2
nd
 pass flueway.
NOTE: 2
nd
 and 3
rd
 pass flueway baffle are not 
interchangeable.
6.  Close the burner swing door and securely seal the 
door to the boiler front section by reinstalling the 
hardware and securing the door using procedure 
previously outlined in Paragraph D of this section.
 NOTICE When securing burner swing door make 
sure door is drawn-in equally on both sides.