Specifications
20
21
Model Application Installation Function
Zone Control
Panels and Kits
System Type
Number of Zones
Expansion Capacity
Includes
Terminals
Installer Setup
Standardized Menu
Driven Checkout
Procedure
Operating Tempe-
ratures
Wire Channels
Color Coded
Labeling
Zip Tie Anchor
Mounts
24V Power
SP Dual Fuel
Variable Spped Fan
Control
Communicating
Zone of Greatest
Demand Intelligence
Stage Control
Auto Re-Setting
Circuit Breaker
Discharge
Temperature
Displayed
HZ432
3 Heat / 2 Cool Conventional
3 Heat / 2 Cool Heat Pump
2 Heat / 2 Cool Dual Fuel
4
Up to 32
Zones
HZ432 TrueZONE Panel
Push
Terminals.
2 Wires Per
Terminal
Digital Menu • -40 - 165 F • • • • • •
Thermostat, Timer,
or % of
zones calling
Per Zone •
HZ432K
3 Heat / 2 Cool Conventional
3 Heat / 2 Cool Heat Pump
2 Heat / 2 Cool Dual Fuel
4
Up to 32
Zones
HZ432 TrueZONE Panel, C7735
Discharge Air Temperature
Sensor (DATS), AT140 Transformer
Push
Terminals.
2 Wires Per
Terminal
Digital Menu • -40 - 165 F • • • • • •
Thermostat, Timer,
or % of
zones calling
Per Zone •
HZ322
2 Heat / 2 Cool Conventional
2 Heat / 1 Cool Heat Pump
3 No HZ322 TrueZONE Panel
Push Terminals.
2 Wires Per
Terminal
Digital Menu • -40 - 165 F • • • • •
Thermostat, Timer,
or % of
zones calling
Per Zone •
HZ322K
2 Heat / 2 Cool Conventional
2 Heat / 1 Cool Heat Pump
3 No
HZ3 22 True ZON E Panel,
C7735 Discharge Air Temperature
Sensor (DATS), AT140 Transformer
Push
Terminals.
2 Wires Per
Terminal
Digital Menu • -40 - 165 F • • • • •
Thermostat, Timer,
or % of
zones calling
Per Zone •
HZ311 1 Heat/1 Cool Conventional 3 No HZ311 TrueZONE Panel
Push Terminals.
2 Wires Per
Terminal
None • -40 - 165 F • • • • • NA Per Zone
HZ311K 1 Heat/1 Cool Conventional 3 No
HZ311 TrueZONE Panel, C7735
Discharge Air Temperature
Sensor (DATS), AT140 Transformer
Push Terminals.
2 Wires Per
Terminal
None • -40 - 165 F • • • • • NA Per Zone
HZ221
2 Heat/1 Cool
Heat Pump with Auxiliary
2 No HZ221 TrueZONE Panel
Push Terminals.
2 Wires Per
Terminal
None • -40 - 165 F • • • • • NA Per Zone
HZ221K
2 Heat/1 Cool
Heat Pump with Auxiliary
2 No
HZ221 TrueZONE Panel, C7735
Discharge Air Temperature
Sensor (DATS), AT140 Transformer
Push Terminals.
2 Wires Per
Terminal
None • -40 - 165 F • • • • • NA Per Zone
Wireless Zoning Systems Selection Guide
Solutions Schedule Options User Interface Applic ation Power Method Features and Functions Display Information Limited Warranty Wiring Terminals
Kit Includes:
Relocate Thermostat Without Running
New Wires
Upgrade to Multi-stage or Add Cooling
Without Running New Thermostat Wires
Add to a TrueZONE
®
System Without
Running New Thermostat Wires
Displays Outdoor Temperature and
Humidity
Add Duel Fuel Control Without
Running Wires To Outdoor Sensor
Program Options
ENERGY STAR
®
Temporary Override
Permanent Hold
Stages
Gas, Oil or Electric
Heat Pump
Forced Warm Air
Permanent Memory Retention
Selectable Auto or Manual
Changeover
Adaptive Intelligent
Recovery
™
/Early Start
™
Temperature Setpoint Limits
Remote Locator
Display Size (Viewable sq. in.)
On-Demand Backlighting
Simultaneous Display of
Room and Set Temperatures
Private Labeling Available
Programmable Wireless Zoning Adapter Kit
YTH6320R1023
Programmable FocusPRO
and Wireless Adapter
• • • •* •**
5-1-1/
5-2/Day
• • • Soft Keys
Up to 3H/2C Heat Pump
or 2H/2C Conventional
• • •
FocusPRO — Battery
Wireless Adapter - Hardwired
• • • • • 5.09 • • • 5 years
Wireless Adapter
- A, B, C, D
Non-Programmable Wireless Zoning Adapter Kit
YTH5320R1025
Non-Programmable
FocusPRO and Wireless Adapter
• • • •* •** Soft Keys
Up to 3H/2C Heat Pump
or 2H/2C Conventional
• • •
FocusPRO — Battery
Wireless Adapter - Hardwired
• • • • 5.09 • • • 5 years
Wireless Adapter
- A, B, C, D
Conventional and Networked Zoning System Selection Guide
Model Application Installation Features Cros-Reference
Zone Dampers
Application
Actuation
Number of Wires
Range Stops
Voltage
VA
Motor Timing
Sizes
Limited Warranty
EWC
ZoneFirst
April Aire
ARD Supply Damper
Spring Return
Open
(Reversible)
2 Yes 24 V 6 VA
30 seconds
closed / 10
seconds spring
return open
5, 6, 7, 8, 9, 10,
12, 14, 16, 18, 20
5 years RSD RDS
6500 Series,
6600 Series
EARD
Supply /
Ventilation Damper
Spring Return
Closed
(Reversible)
2 Yes 24 V 6 VA
30 seconds open
/ 10 seconds
spring return
closed
5, 6, 7, 8 5 years RSD RDS
6500 Series,
6600 Series
ZD Supply Damper
Spring Return
Open
2 Yes 24 V 6 VA
30 seconds
closed / 10
seconds spring
return open
6X6 to 28X20 5 years ND-RSD ZD
6700 Series,
6800 Series
RRD Supply Damper
Power Open /
Power Closed
3 Yes 24 V 2.5 VA 90 seconds 5, 6, 7, 8 5 years SID 6706
MARD
Supply / Bypass
Damper
Power Open /
Power Closed
3 Yes 24 V 2.1 VA 90 seconds
6, 8, 10, 12, 14,
16, 18
5 years URD RDM 6200 Series
SPRD Bypass Damper Weighted Arm 0 No NA NA NA
7, 8, 10, 12,
1 4 , 1 6
5 years
PRD,
PRD-RD
SPRD 6900 Series
Cross-Reference
Compatible with
RedLINK™ Wireless
Controls
Footprint
Covered Electronics
Limited Warranty
ECW
ZoneFirst
APril Aire
Arzel
• 8" X 13.5" Yes 5 Year
ST-2, ST-3,
UZC, BMPlus,
NCM-300
MMZ3,
MMH3,
MZS4
6202, 6203,
6302, 6303,
6404
200
Series, Heat
PumPRO,
AirBoss
• 8" X 13.5" Yes 5 Year
ST-2, ST-3,
UZC, BMPlus,
NCM-300
MMZ3,
MMH3,
MZS4
6202, 6203,
6302, 6303,
6404
200
Series, Heat
PumPRO,
AirBoss
• 8" X 11.5" • 5 Year
ST-2, ST-3,
BMPlus
MMZ3,
MMH3
6202, 6203,
6302, 6303
200 Series,
Heat PumPro
• 8" X 11.5" • 5 Year
ST-2, ST-3,
BMPlus
MMZ3,
MMH3
6202, 6203,
6302, 6303
200 Series,
Heat PumPro
8" X 8.25" • 5 Year ST-2, ST-3 MMZ3 6202, 6203
8" X 8.25" • 5 Year ST-2, ST-3 MMZ3 6202, 6203
8” X 8.25” • 5 Year
8” X 8.25” • 5 Year
* C7089R1013 Required ** REM5000R1001 Required