Install Instructions
3
B. Maintenance
1. On a continuous basis:
• Keeptheareaaroundtheboilerfreefrom
combustible materials, gasoline, and other
ammablevaporsandliquids.
• Keeptheareaaroundthecombustionairinlet
terminal and the area around the boiler free
from contaminants, including all sources of
hydrocarbons such as bleaches, fabric softeners,
chemicals, sprays, cleaners, paints, paint
removers, refrigerants, and cat boxes. Traces
of these chemicals can be drawn into the boiler,
causing severe corrosion damage to the boiler
and/or objectionable odors.
A. General
1. This manual covers the proper care and use of
theAlpine™CondensingHighEfciencyGasFired
Boiler.
2. Instructions to safely operate and shut down
thisboilerareshowninFigure2onpage5,aswell
asonalabelafxedtotheboiler.Controllocations
showninFigure1.
3. Flame Failure: The boiler control will shut
offgastotheburnerintheeventofamefailure.
Ifboilerfailstore,callaqualiedgasservice
technician to diagnose and correct the problem.
4. Combustion Air/Vent System Blockage: The
boiler control will shut down the burner if there is
a blockage in the combustion air or vent pipe such
asabee’snestorice.Ifboilerfailstore,calla
qualiedgasservicetechniciantodiagnoseand
correct the problem. After removing a blockage, it
may be necessary to press the control reset button to
restart the boiler.
WARNING
Asphyxiation Hazard. In the event that the
ignition system on an Alpine boiler does
not permit the boiler to re, there is either a
problem with the ignition system or a problem
with the vent system. Call a qualied gas
service technician to diagnose and correct
the problem.
A shutdown of the burner due to the pressure
switch is an indication that there is a problem
with the vent system, such as a blockage. The
boiler pressure switch should only be reset
after a qualied gas service technician has
diagnosed and corrected the venting problem
that caused the pressure switch to open.
• Keeptheboilerroomventilationopeningsopen
and unobstructed.
• Donotexposetheboilertolargeamountsofdust
such as that generated by drywall construction or
woodworking.
2. On a monthly basis:
WARNING
If any of the below listed conditions is found,
follow instructions “TO TURN OFF GAS TO
APPLIANCE” in Figure 2 and contact a qualied
gas service technician to correct the problem
before placing the boiler back in service. Failure
to correct these conditions could result in
property damage, personal injury or loss of life.
• Inspectventandcombustionairintaketerminals
for obstruction or damage due to impact or
excessive temperature.
• Inspectventandcombustionairexteriorwall
penetrations to be sure they are weather tight.
• Inspecttheventandcombustionairintake
system for obstructions, loose joints, condensate
leakage, sags in horizontal runs of pipe,
corrosion, or other deterioration.
• Inspectwaterandgaslinesforleaks.
• Removeboilerfrontdoorandinspectforcarbon
(soot) in or near the burner compartment,
condensate drain leaks or blockage, or
deterioration of the visible controls, wiring, or
sheet metal components.
• Inspectamefortrueyellowtipping.Adjust
thermostat to highest setting to turn on boiler and
viewamesthroughobservationglasswithfront
doorremoved.Onhighretheameshouldbe
stable and mostly blue. No true yellow tipping
shouldbepresent,howeverintermittentecksof
yellowandorangeintheamecausedbydustin
airarenormal.SeeFigure3.Iftheburnerame
looks satisfactory, adjust thermostat to normal
setting and reinstall boiler front door.
3. On an annual basis:haveaqualiedgasservice
technician perform a more detailed inspection
of the burner, heat exchanger, controls, and vent
systemandprovidemaintenanceasspeciedinthe
Installation, Operating, and Service Instructions.