Cut Sheet

3
SECTION 6. ACCIDENTAL RELEASE MEASURES
Internal cell materials, such as electrolyte leaked from battery cell, are carefully dealt with according to the followings:
Personal Precautions: Forbid unauthorized person to enter. Remove leaked materials with protective equipment written in section 8.
Environmental Precautions: Do not throw out into the environment.
Method Of Recovery and Neutralization: Dilute the leaked electrolyte with water and neutralize with diluted sulfuric acid. Any
exposed solid that contains the electrolyte is to be placed into a container. The area exposed to the electrolyte should be fully flushed
with water.
SECTION 7. HANDLING AND STORAGE
Handling
Technical Measures:
Prevention Of User Exposure: Not necessary under normal use
Prevention Of Fire and Explosion: Not necessary under normal use
Precaution For Safe Handling: Do not damage or remove the external tube
Specific safe handling advice: Never throw out cells in a fire or expose to high temperatures. Do not soak cells in water and
seawater. Do not expose to strong oxidizers. Do not give a strong mechanical shock or throw
down. Never disassemble, modify or deform. Do not connect the positive terminal to the negative
with electrically conductive material. In case of charging, use only a charger specified by Makita.
Storage
Technical Measures:
Storage Conditions (suitable to be avoided): Avoid direct sunlight, high temperature, high humidity. Store in cool places
(temperature: -20 ~ 30 degree C, humidity: from 40 to 80%).
Incompatible Products: Conductive materials, water, seawater, strong oxidizers and strong acids.
Packing Material (recommended, not suitable): Insulative and tear-proof materials are recommended.
SECTION 8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
Engineering Measures:
No engineering measure is necessary during normal use. In case of internal cell materials' leakage, the information below will be
useful.
Control Parameters:
Common Chemical Name / General Name
ACGIH (2007)
TLV-TWA BEI
Nickel, Nickel Compounds (As Ni)
Metal: 1.5mg/m
3
Soluble compounds: 0.1mg/m
3
Insoluble compounds: 0.2mg/m
3
-
Cobalt Compounds (As Co)
0.02mg/m
3
In urine: 15 micro g/l
In blood: 1 micro g/l
Manganese Compounds (As Mn)
0.2mg/m
3
-
Aluminum Compounds (As Al)
5mg/m
3
(Flammable powder) -
Zinc Oxide
2mg/m
3
-