Owner's manual

68
6. REMOVAL / INSTALLATION OF INDIVIDUAL
SEGMENTS
6.1. Removal
Supply segments
Release required module by actuating the locking element and swivel out.
In the case of the pressure gauge module ensure that the hose is disconnected from the pneumatic module
(see figure: Hose connection of the pressure gauge module).
Fig. 10: Removal / installation of a supply segment
Valve segments
Remove valves and any protective caps from the plug-in contacts (either depressurized or all affected loca-
tions with P-shutoff).
Release the electronic module by actuating the locking element in the direction of the arrow and swivel out the
module (see figure: Removal / installation of the valve segment).
entriegeln
Fig. 11: Removal / installation of a valve segment
Type 8650
english