Owner's manual
53
7.1.3. Ordering Chart
Description
Orifice
QNn-
value
air
Rated power
Pressure range
Switching
times
Ident no.
Opening
Closing
[l/min] [W] [bar] [ms] [ms]
C = NC (normally closed)
12
3
2
1
10
3/2-way valve, pilot controlled, current-
free, outlet port 2 relieved
4 300 0.3 2.5 ... 7 35 45 184 766
186 832
2)
0.3 1... 8
1)
35 45 186 831
1)
186 833
1, 2)
0.3 1 ... 7 35 45 186 835
1)
2 x C = NC (normally closed)
2
1
3
12
10
10
14
1
3
4
3/2-way valve, pilot controlled,
current-free, outlet port 2 relieved
4 300 2 x 0.3 2.5 ... 7 20
3)
25 182 086
2 x 0.3 1 ... 8
1)
20
3)
25 182 088
1)
D = NO (normally open)
12
3
2
1
10
2 x 3/2-way valve, pilot controlled,
current-free,
outlet port 2 and 4 relieved
4 300 0.3 2.5 ... 7 35 45 184 767
184 768
2)
H
12
3
2
5
14
1
4
5/2-way valve, pilot controlled,
current-free,
outlet port 1 with outlet port 2,
outlet port 4 vented
4 300 0.3 2.5 ... 7 35 45 184 769
184 773
2)
0.3 1 ... 7 35 45 186 834
1)
1)
Version with auxiliary control air
2)
Without manual override
3
) Please observe the information for the characteristics of the 8-channel modules in the chapter “Start-up”,
section “Acyclic parameters of the AirLINE Ex modules”!
5/3-way function with locked mid-position:
This function can be implemented with the delockable double check valve, Type 0498 (control is by 2x 3/2-way
function).
Type 8650
english
Configuration and Function of the
Modules