Owner's manual
45
NOTE!
Pressure supply!
When using the P shut-off basic modules, ensure that the pressure supply to the valve islands is
configured with a sufficiently large volume. (Minimum hose diameter 8/6 mm)
4.2.4. Overview
3
5
6
7
8
9
2
1
4
Legend
1
2
3
4
5
6
7
8
9
check valve (optional)
Labeling of valve positions and installed
options
Inclined tie rods
Service ports
(assignment dependant on valve type)
Flange for valve
P shut-off (optional, only for certain versions)
X channel
R- & S channel
P channel
Fig. 16: Overview - Basic pneumatic module (Station width: 44 mm, with the options check valves and P shut-off)
4.3. Pneumatic Connections
1
2
Possible configuration of the service ports
Position
Valves
Double
valves
3/2-way 5/2-way 2x 3/2-way
6524/6526 6525/6527 6524/6526
1 not used 2 2 (valve 12)
2 2 4 4 (valve 14)
Fig. 17: Possible configuration of the service ports - basic pneumatic module
4.4. Accessory
Basic pneumatic module - Accessory Ident nr.
Plug to block P-channel
(to build up several pressure levels or medium groups in a AirLINE Ex system type 8650)
655 068
Type 8650
english
Configuration and Function of the
Modules