User guide
162 - 8645
English
All connection variants are suitable for the same mounting bore and can be
subsequently interchanged.
Illustration: Connection variants
•
•
Danger may result from loosening the pneumatic connector.
Pressure may only be connected once all the safety clamps have been attached cor-
rectly.
Pay attention that the safety clamps are fitted correctly.
Leaking connectors
can result from old, damaged or unsuitable gaskets.
Pay attention to the condition of the gaskets.
Take care that the seal is not damaged during assembly.
1
Legend
1 Safety clamp
Illustration: Changing the pneumatic connectors
Proceed as follows when changing the pneumatic connectors:
Pull out the safety clams (see illustration) with using a screwdriver.
Remove the pneumatic connector.
Install the new pneumatic connector.
Reattach the safety clamps.