Manual

32
GB
RIO MODULE
Technical Data
Operating voltage 24 V; -15 % / +20 %
Residual ripple 2 V
ss
Current consumption
Inputs / Logic max. 1 A
Outputs max. 4 A (M12)
Overview
Detail drawing Diagnostic / Status LEDs (20)
RIO Status U
i
Logic vol-
tage
F
S
Error
select
U
O
Output
voltage
F
N
Error
number
U
S
Sensor
voltage
33
GB
13
22
50
20
8
9
23
51
52
53
18
19
26
8 FE contact
9 FE contact
13 Type plate
18 Rotary encoder switch
(x1)
19 Rotary encoder switch
(x10)
20 Diagnostic/Status LEDs
(see detail drawing)
22 Label panel Power
23 Connection Power
26 Diagnostic and update
interface
50 Label panel RIO IN
51 Connection
RIO IN (M8)
52 Label panel RIO OUT
53 Connection
RIO OUT (M8)
34
GB
Electrical connections
Voltage supply M12, plug 4-pin, max. 4 A
RIO incoming M8, jack
RIO outgoing M8, jack
Address setting via rotary encoder switch
Address range 0 ... 49
Integrated diagnostic
interface 3-pin, (RM 2.54)
Diagnostic LEDs 2 x RIO status
2 x fault indication
3 x supply voltage
Connection table
PIN RIO IN /
RIO OUT
Power / Supply Voltage
1 CAN_H +24 V Output (U
o
)
2 CAN_L +24 V Logic / Sensors (U
i
)
3 FE GND Logic / Sensors (U
i
)
4 _ GND Output (U
o
)
35
GB
PNEUMATIC CONNECTIONS
Field bus- / Multipole- /
RIO-module
Intermediate module
(Inside)
42
44
43
45
1
3/5
82/84
12/14
Ext.
Int.
Push
Turn
42
44
43
45
47
42 Auxiliary control air M5, D6, D4, D1/4“
43 Pilot exhaust air M5, D6, D4, D1/4“
44 Exhaust air G1/4“, NPT1/4“, D10
45 Compressed air supply G1/4“, NPT1/4“, D10
47 Switching between external / internal auxiliary con-
trol air. Connector 12/14 must be closed for internal
auxiliary control air.