User Manual

8
Assembly
5.3.2. Fluid connection
Type 6524
3/R
X*
2/A
1/P
Type 6525
X*
5/R
4/A
1/P
2/B
3/S
Design the pressure supply
with the largest possible
volume!
X* - pilot control exhaust air
Fig. 2: Fluid connection. Types 6524 and 6525
5.3.3. Fluid and electrical connection
Type 6524
(2 x 2/3-way valve)
12
14
- Pin coil 12
controlled via bit
“n+1”
- Pin coil 14
controlled via bit
“n”
+ Pin
X*
5/R
4/A
1/P
2/B
3/S
Bit “n+1”
Bit “n”
Observe pin
assignment!
X* - pilot control
exhaust air
Hand lever
assignment
Fig. 3: Fluid and electrical connection. Type 6524
6. ASSEMBLY
6.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
Before loosening lines or valves, turn off the pressure and vent
the lines.
Risk of injury due to electrical shock!
Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations
for electrical equipment!
WARNING!
Risk of injury from improper assembly!
Installation may only be carried out by authorized technicians with
the appropriate tools!
Risk of injury from unintentional activation of the system and
uncontrolled restart!
Secure system from unintentional activation.
Following assembly, ensure a controlled restart.
english
Type 8644