Technical data
Housing dimensions (width x height x depth) 61 mm x 71 mm x 120 mm
(incl. snap-on hooks)
Weight without Electronic pressue module 220 g
with Electronic pressure module 247 g
Permissible temperature (storage/transport) -20 °C to +60 °C
Permissible air humidity 75% mean, 85% occasionally
ATTENTION!
In the range of 0 to +55 °C, suitable precautions must be taken against elevated humidity
(> 85%).
Slight condensation of short duration on the outside of the housing is permissible, e.g.
when the terminal is brought from a vehicle into a closed room.
Permissible air pressure (operation) 80 kPa to 106 kPa (up to 2000 m üNN)
Permissible air pressure (storage/transport) 70 kPa to 106 kPa (up to 3000 m üNN)
Protection type IP 20 to IEC 60529
Protection class Class 3 to VDE 106, IEC 60536
Performance characteristics seen from the overall system
Cover / Manometer Electronic pressure measurement module
logical no process diagramm, hence no adequate electrical module
address required
mechanical 47 mm installation dimension 47 mm installation dimension
electrical no current consumption 66 mA
fluidic lefd-hand limitation of valve block, lefd-hand limitation of valve block,
left-hand supply left-hand supply