Installation
Before reaching into the device or the equipment,• switch off the power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations for electrical equipment!•
The valve block of the AirLINE system Type 8644 is combined with the I/O system 750 from Wago.
The valve block is bolted securely onto the standard rail. Additional electrical modules / terminals can be aligned in
rows on the sides of the valve block.
Detach the adjacent modules / terminals (if fitted).
→
Release the attachment of the valve block on the standard rail. To do this, turn the fastening screws all the way →
counter-clockwise.
Lift the valve block vertically off the standard rail.
→
Releasing the attachment of the valve block on the standard railFigure 30:
There must be adequate space between valve block and predecessor module > 6 mm.
Detach the modules / terminals from the standard rail according to the manufacturer’s description.
→