Start-Up
10.3.1. Selection of the modules in the GSD file
The module designations of the different electrical base modules in the GSD file can be found in the following table.
Add-on dimension Module designation Entry in GSD file
11 mm
ME02 / 2-fold monostable 2 Valves 3/2, 5/2 monostable 2DO
2 Valves 3/2, 5/2 monostable* 2DO
ME02 / 2-fold 2 x monostable 2 Double Valves 3/2 monostable 4DO
2 Double Valves 3/2 monostable* 4DO
ME02 / 4-fold monostable 4 Valves 3/2, 5/2 monostable 4DO
4 Valves 3/2, 5/2 monostable* 4DO
ME02 / 2-fold bistable 2 Valves 5/3, 5/2 impulse 4DO
2 Valves 5/3, 5/2 impulse* 4DO
16 mm
ME03 / 2-fold monostable 2 Valves 3/2, 5/2 monostable 2DO
2 Valves 3/2, 5/2 monostable* 2DO
ME03 / 4-fold monostable 4 Valves 3/2, 5/2 monostable 4DO
4 Valves 3/2, 5/2 monostable* 4DO
ME03 / 3-fold monostable 3 Valves 3/2, 5/2 monostable 4DO**
3 Valves 3/2, 5/2 monostable* 4DO**
ME03 / 2-fold monostable 2 Valves 5/3, 5/2 impulse 4DO
2 Valves 5/3, 5/2 impulse* 4DO
* Module is combined with predecessor module, for utilization of the data byte
** One bit remains unassigned
Connection modules and intermediate feeds are not bus users and are not considered!