Instruction Manual

57
Installation
Place new function module vertically on the distributor module (backplane bus) and press down until it clicks
into position.
Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws
according to the following assembly diagram (see “Figure 30: Tightening the screws”).
20 Ncm
20 Ncm
30 Ncm
30 Ncm
Figure 30: Tightening the screws
8.5. Fluid Installation
DANGER!
Risk of injury from high pressure in the equipment!
• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.
• Design the connections with the largest possible volume.
• Close the open connections not required with lock screws.
• The connections for the pilot control exhaust air (x) must not be sealed.
• Check that connections 1 and 3 or 5 have been configured correctly; these must not be mixed up.
english