Instruction Manual
38
Structure and function of the modules
Combination options (electronic base module / valve)
Base module type Add-on
dimension
Valve locations Valve type Operating principle
ME02 2-fold
monostable
11 mm 2 6524 3/2-way
6525 5/2-way
2-fold
bistable
11 mm 2 0460 5/3-way
5/2-way impulse
2-fold
2 x monostable
11 mm 2 6524 2 x 3/2-way
4-fold
monostable
11 mm 4 6524 3/2-way
6525 5/2-way
ME03 2-fold
monostable
16.5 mm 2 6526 3/2-way
6527 5/2-way
2-fold
bistable
16.5 mm 2 0461 5/3-way
5/2-way impulse
3-fold
10 mm monostable*
11 mm 3 6524 3/2-way
6525 5/2-way
4-fold
monostable
16.5 mm 4 6526 3/2-way
6527 5/2-way
* with 10 mm valves
The connector strip situated under a shielding plate near the electronic base modules is guided by a protective
plastic collar. Placing these modules in rows and connecting them together ensure that this shielding plate
and the plug pins are not damaged or bent.